Troubleshooting high availability issues
-
Issue The inability of the NetScaler appliances to pair the NetScaler appliances in a high availability setup.
-
CauseNetwork connectivityResolutionVerify that both the appliances are connected to the switch and the interfaces are enabled.
-
CauseMismatch in the Password for the default Administrator accountResolutionVerify that the password on both the appliances is the same.
-
CauseIP conflictResolutionVerify that both the appliances have unique NetScaler IP (NSIP) address. The appliances should not have the same NSIP address.
-
CauseNode ID mismatchResolutionVerify that the Node ID Configuration on both the appliances is unique. The appliances should not have the same Node ID configuration. Additionally, you must assign value for a Node ID between 1 and 64.
-
CauseMismatch in the password of the RPC nodeResolutionVerify that both the nodes have the same RPC node password.
-
CauseAn administrator has disabled the remote nodeResolutionEnable the remote node.
-
CauseThe Firewall application has blocked the heartbeat packetsResolution
-
-
Issue Both the appliances claim to be the primary appliance.
-
CauseMissing heartbeat packets between the appliancesResolutionVerify that the UDP port 3003 is not blocked for communication between the appliances.
-
-
Issue The NetScaler appliance is not able to synchronize the configuration.
-
CauseA Firewall application is blocking the required port.ResolutionVerify that the UDP port 3010 (or UDP port 3008 with secure synchronization) is not blocked for communication between the appliances.
-
CauseAn administrator has disabled synchronization.ResolutionEnable synchronization on the appliance that has the issue.
-
CauseDifferent NetScaler releases or builds are installed on appliances.ResolutionUpgrade the appliances to the same NetScaler release or build.
-
-
Issue Command propagation fails between the appliances.
-
CauseA Firewall application is blocking the port.ResolutionVerify that the UDP port 3011 (or UDP port 3009 with secure propagation) is not blocked for communication between the appliances.
-
CauseAn administrator has disabled command propagation.ResolutionEnable command propagation on the appliance that has the issue.
-
CauseDifferent NetScaler releases or builds are installed on appliances.ResolutionUpgrade the appliances to the same NetScaler release or build.
-
-
Issue The NetScaler appliances in the high availability pair are unable to run the force failover process.
-
CauseThe Secondary node is disabled.ResolutionEnable the secondary node.
-
CauseThe Secondary node is configured to stay secondary.ResolutionSet the secondary high availability status of the secondary node to Enable from Stay Secondary.
-
-
Issue The secondary appliance does not receive any traffic after the failover process.
-
CauseThe upstream router does not understand GARP messages of NetScaler appliance.ResolutionConfigure virtual MAC address on the secondary appliance.
-