Perform power control operations by using the LOM port
Perform power control operations by using the GUI
-
In the Menu bar, click Remote Control.
-
Under Options, click Power Control, and then select one of the following options:
-
Reset System—Gracefully restart the appliance. All operations on the appliance are stopped, no new connections to the client or server are accepted, and all existing connections are closed before the appliance restarts. This option is similar to a warm restart, such as by entering the reboot command. The BMC does not reboot itself during this operation.
-
Power Off System – Immediate—Disconnect power to the appliance immediately, without gracefully shutting down the appliance. The BMC continues to operate normally in this mode to allow the user to remotely power on the appliance. This option is the same as pushing the power button until the unit powers off.
-
Power Off System – Orderly Shutdown—Gracefully shut down the appliance, and then disconnect power to the appliance. Has the same effect as pressing the power button on the back panel of the appliance for less than four seconds. All operations on the appliance are stopped, no new connections to the client or server are accepted, and all existing connections are closed before the appliance shuts down. The BMC continues to operate normally in this mode to allow the user to remotely power on the appliance. This option is the same as entering the shutdown command in the appliance shell.
-
Power On System—Switch on the appliance. The BMC does not reboot itself during this operation. This option is the same as pushing the power button.
-
Power Cycle System—Switch off the appliance, and then turn it back on. The BMC does not reboot itself during this operation. This option is the same as pushing the power button until the unit powers off, and then pushing the power button to power on the unit.
-
-
Click Perform Action.
Perform a power cycle of the BMC
Perform power control operations on the BMC by using the appliance shell
ipmitool mc reset warm
Perform a warm restart remotely from another computer on the network
ipmitool –U <bmc_gui_username> –P <bmc_gui_password> –H <bmc IP address> mc reset warm
Perform a cold restart of the LOM from the appliance
ipmitool mc reset cold
Perform a warm restart remotely from another computer on the network
ipmitool –U <bmc_gui_username> –P <bmc_gui_password> –H <bmc IP address> mc reset cold
Perform a core dump
Perform a core dump by using the GUI
-
In the Menu bar, click Remote Control.
-
Under Options, click NMI, and then click Initiate NMI.
Perform a core dump remotely from another computer on the network by using the shell
ipmitool -U <bmc_gui_username> -P <bmc_gui_password> -H <bmc IP address> chassis power diag