Upgrade considerations - SNMP configuration
-
APPFW-BUFFER-OVERFLOW
-
APPFW-COOKIE
-
APPFW-CSRF-TAG
-
APPFW-DENY-URL
-
APPFW-FIELD-CONSISTENCY
-
APPFW-FIELD-FORMAT
-
APPFW-POLICY-HIT
-
APPFW-REFERER-HEADER
-
APPFW-SAFE-COMMERCE
-
APPFW-SAFE-OBJECT
-
APPFW-SQL
-
APPFW-START-URL
-
APPFW-VIOLATIONS-TYPE
-
APPFW-XML-ATTACHMENT
-
APPFW-XML-DOS
-
APPFW-XML-SCHEMA-COMPILE
-
APPFW-XML-SOAP-FAULT
-
APPFW-XML-SQL
-
APPFW-XML-VALIDATION
-
APPFW-XML-WSI
-
APPFW-XML-XSS
-
APPFW-XSS
-
CLUSTER-BACKPLANE-HB-MISSING
-
CLUSTER-NODE-HEALTH
-
CLUSTER-NODE-QUORUM
-
CLUSTER-VERSION-MISMATCH
-
COMPACT-FLASH-ERRORS
-
CONFIG-CHANGE
-
CONFIG-SAVE
-
HA-BAD-SECONDARY-STATE
-
HA-NO-HEARTBEATS
-
HA-SYNC-FAILURE
-
HA-VERSION-MISMATCH
-
HARD-DISK-DRIVE-ERRORS
-
HA-STATE-CHANGE
-
HA-STICKY-PRIMARY
-
PORT-ALLOC-FAILED
-
SYNFLOOD
-
Release 11.1 build 61.2 or later
-
Release 12.0 build 61.0 or later
-
Release 12.1 build 30.1 or later
-
Release 13.0 build 51.4 or later
Example
CLUSTER-NODE-HEALTH SNMP alarm is set up by using the NetScaler command line:
> set snmp alarm CLUSTER-NODE-HEALTH -time 111 -state DISABLED -severity Major
> save config
ns.conf) as:
set snmp alarm CLUSTER-NODE-HEALTH -time 111 -state DISABLED -severity Major -timeout 86400
May 23 09:14:46 <local0.err> ns nsconfigd: __init_config_filter(): (null) line 0: No such argument [-timeout]>> set snmp alarm CLUSTER-NODE-HEALTH -time 111 -state DISABLED -severity Major -timeout 86400.
Workaround
-
Before the upgrade, remove the timeout setting from the SNMP configurations in the saved configuration file (ns.conf).
-
After the upgrade, reconfigure the SNMP alarms without the timeout parameter.