Configure the network settings on the LOM port
ipmitool utility. Using the ipmitool utility remotely, you can:
-
Determine the LOM firmware version number.
-
Perform warm and cold restarts.
-
Configure LOM network settings.
-
Monitor the health of the appliance.
-
Perform power control operations.
<http://ipmitool.sourceforge.net/>. The ipmitool utility is also included in NetScaler MPX and CloudBridge/SDX (dom0) appliances for initial LOM port network configuration. When using the shell, you can choose to use DHCP or static IP settings for initial network configuration. After configuring the network settings, you can use the ipmitool commands over the network. For example, the BMC firmware revision command would need the same user name, password, and IP address that is used to access the BMC/LOM GUI port.
-
Take a closer look at network firewall settings and access control list (ACL) policies of all network devices along the network path.
Configure the NetScaler LOM port by using the GUI
-
In a web browser, type
<http://192.168.1.3>and enter the default user credentials.Note:The NetScaler LOM port is preconfigured with IP address 192.168.1.3 and subnet mask 255.255.255.0. -
On the Configuration tab, click Network and type new values for the following parameters:
-
IP Address—IP address of the LOM port
Note:You can configure an IPv6 address on MPX/SDX models 8900, 15000, 16000, 26000, and 9100 using either the Web UI oripmitool lan6commands.-
Subnet Mask—Subnet mask used to define the subnet of the LOM port
-
Default Gateway—IP address of the router that connects the LOM port to the network
-
-
Click Save.
-
If you want to change the user credentials, navigate to Configuration > Users, select the user, click Modify User, and change the credentials.
Configure the NetScaler LOM port by using the shell
-
Configure the IP addressing mode:
-
To use DHCP, at the shell prompt, type:
ipmitool lan set 1 ipsrc dhcpNo further IP-level configuration is required. -
To use static addressing, at the shell prompt type:
-
ipmitool lan set 1 ipsrc static -
ipmitool lan set 1 ipaddr <LOM IP address> -
ipmitool lan set 1 netmask <netmask IP address> -
ipmitool lan set 1 defgw ipaddr <default gateway IP address>
The BMC reboots to apply the changes. Pings to the BMC succeed after approximately 60 seconds. -
-
-
Optionally, to configure Ethernet VLAN ID and priority, at the NetScaler shell prompt type:
-
ipmitool lan set 1 vlan id <off|<ID>> -
ipmitool lan set 1 vlan priority <priority>
You can either disable or enable the VLAN. Set the VLAN ID to a value from 1 to 4094, and the VLAN priority to a value from 0 to 7. After the network settings have been correctly applied, you can access theipmitoolremotely from a physically separate machine over the network. For remote access, enter the BMC user name, BMC password, and the BMC IP address. For example, to run theipmitool mc infocommand, at the shell prompt on a remote machine, type:ipmitool –U <username> –P <password> –H <bmc IP address> mc info -
Obtain health monitoring information
-
If the failure is gradual enough for the main CPU to issue an SNMP alert. An electrical failure close to the CPU, such as a failed electrical capacitor, occurs too quickly for the CPU to issue an alert.
-
If the failure happens after the BIOS, Operating System, and SNMP service have started and normal boot-up has been successful.
-
If the failure happens while the operating system and other system software are in a stable enough state for the SNMP software service to run.
-
In the Menu bar, click System Health.
-
Under Options, click Sensor Readings.
Install the MIB
<http://www.net-snmp.org/tutorial/tutorial-5/commands/snmptrap.html>. For the exact steps of this procedure specific to your environment, contact your SNMP network monitoring software provider.
Configure SNMP alerts
Configure SNMP alerts on the LOM by using the GUI
-
Download the IPMI View utility from
<ftp://ftp.supermicro.com/utility/IPMIView/>and install it on your computer. Use this utility to test the configuration. For more information, see the section about configuring the alert settings in the IPMI View User Guide at<http://supermicro.com>. -
Open the IPMI View utility.
-
In the LOM GUI, navigate to Configuration > Alerts, click Alert No 1, and then click Modify.
-
Select the severity level of the events for which to generate alerts.
-
Set Destination IP to the IP address at which you installed the IPMI View utility.
-
Optionally, to receive alerts by email, specify an email address. To avoid receiving email for routine alerts, specify a severity higher than Informational.
-
Click Save.
-
The LOM starts sending alerts to the IPMI View utility within in a minute or two. After the IPMI View utility starts receiving alerts from the LOM, reconfigure the destination IP address to point to your SNMP Network Management Software, such as HP OpenView.
Set up SNMP alerts on the LOM by using the NetScaler shell
<http://www.intel.com/content/www/us/en/servers/ipmi/ipmi-specifications.html>
Set up SNMP filters
ipmitool raw 4 0x12 0x6 0x10 0x80 1 1 0 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0 0xff 0 0 0xff 0 0 0xff 0
Set up a policy list
ipmitool raw 4 0x12 9 0x10 0x18 0x11 0x81
Set up the destination address for SNMP events
ipmitool lan alert set 1 1 ipaddr <x.x.x.x>
Specify an SNMP community string name
ipmitool lan set 1 snmp <community string>